Eccentricity measuring device - Company Ranking(6 companyies in total)
Last Updated: Aggregation Period:Jul 09, 2025〜Aug 05, 2025
This ranking is based on the number of page views on our site.
Display Company Information
Company Name | Featured Products | ||
---|---|---|---|
Product Image, Product Name, Price Range | overview | Application/Performance example | |
【Specifications】 ○ Measurement Method: Combined Transmission and Reflection ○ Optical System: Microscope method using an autocollimator (f=200mm) with interchangeable objective lenses ○ Objective Lenses (Standard Equipment) ・f= 40mm ・f=100mm ・f=200mm ○ Measurement Range ・Reflection image: R= -100 to +200mm ・Transmission image: f= -100 to +200mm * Wider range of images can be measured with optional objective lenses ○ Resolution (Objective Lenses) ・f= 40mm - 0.104μm ・f=100mm - 0.260μm ・f=200mm - 0.520μm ● For more details, please refer to the PDF document or feel free to contact us. | For more details, please refer to the PDF document or feel free to contact us. | ||
【Specifications】 ○ Measurement Method: Transmission type ○ Applications - Eccentricity measurement (core accuracy measurement) - Centering (lens bonding work) ○ Measured Lenses: Convex lenses, concave lenses, bonded lenses ○ Measurement Range: Effective lens diameter φ3mm or more, BFL ±3mm to ±∞ ○ UBS Camera: Black and white 1/2 inch UBS camera ○ Power Supply: AC adapter AC100V–240V (50Hz/60Hz) ○ Dimensions: 155(W) × 333(H) × 255(D) mm, 4kg ○ Accessories: Main unit, dedicated analysis software, AC adapter, lens holder, dust cover, correction lens ○ Options: Standard three-jaw stage (φ15–φ76mm), large three-jaw stage motorized rotating stage, customized keyboard, UV fiber holder ● For more details, please refer to the PDF document or feel free to contact us. | For more details, please refer to the catalog. Feel free to contact us. | ||
【Specifications】 ○ Measurement method: Reflective type ※ Transmissive/reflective compatible model: "US-A1000" ○ Measurement range ・R=+15mm to -135mm (using 10X objective lens) ・R=+80mm to -125mm (using f=100mm objective lens) ・Lens diameter φ0.5mm and above ○ Minimum reading value ・0.05μm (using 10X objective lens) ・0.30μm (using f=100mm objective lens) ○ External dimensions: 180(W) × 400(H) × 280(D) mm; 6kg ● For more details, please refer to the PDF document or feel free to contact us. | For more details, please refer to the PDF document or feel free to contact us. | ||
---
--- |
--- |
-
- Featured Products
-
Transmissive and reflective dual-purpose eccentricity measuring instrument "TR-A1"
- overview
- 【Specifications】 ○ Measurement Method: Combined Transmission and Reflection ○ Optical System: Microscope method using an autocollimator (f=200mm) with interchangeable objective lenses ○ Objective Lenses (Standard Equipment) ・f= 40mm ・f=100mm ・f=200mm ○ Measurement Range ・Reflection image: R= -100 to +200mm ・Transmission image: f= -100 to +200mm * Wider range of images can be measured with optional objective lenses ○ Resolution (Objective Lenses) ・f= 40mm - 0.104μm ・f=100mm - 0.260μm ・f=200mm - 0.520μm ● For more details, please refer to the PDF document or feel free to contact us.
- Application/Performance example
- For more details, please refer to the PDF document or feel free to contact us.
Through-type eccentricity measuring instrument "CS-A1100"
- overview
- 【Specifications】 ○ Measurement Method: Transmission type ○ Applications - Eccentricity measurement (core accuracy measurement) - Centering (lens bonding work) ○ Measured Lenses: Convex lenses, concave lenses, bonded lenses ○ Measurement Range: Effective lens diameter φ3mm or more, BFL ±3mm to ±∞ ○ UBS Camera: Black and white 1/2 inch UBS camera ○ Power Supply: AC adapter AC100V–240V (50Hz/60Hz) ○ Dimensions: 155(W) × 333(H) × 255(D) mm, 4kg ○ Accessories: Main unit, dedicated analysis software, AC adapter, lens holder, dust cover, correction lens ○ Options: Standard three-jaw stage (φ15–φ76mm), large three-jaw stage motorized rotating stage, customized keyboard, UV fiber holder ● For more details, please refer to the PDF document or feel free to contact us.
- Application/Performance example
- For more details, please refer to the catalog. Feel free to contact us.
Reflective eccentricity measuring instrument (compatible with ultra-small lenses) "US-A1"
- overview
- 【Specifications】 ○ Measurement method: Reflective type ※ Transmissive/reflective compatible model: "US-A1000" ○ Measurement range ・R=+15mm to -135mm (using 10X objective lens) ・R=+80mm to -125mm (using f=100mm objective lens) ・Lens diameter φ0.5mm and above ○ Minimum reading value ・0.05μm (using 10X objective lens) ・0.30μm (using f=100mm objective lens) ○ External dimensions: 180(W) × 400(H) × 280(D) mm; 6kg ● For more details, please refer to the PDF document or feel free to contact us.
- Application/Performance example
- For more details, please refer to the PDF document or feel free to contact us.
-
Membership (free) is required to view all content.
Already a Member? Log In Here