Product Image, Product Name, Price Range overview Application/Performance example
【Specifications】 ○ Measurement Method: Combined Transmission and Reflection ○ Optical System: Microscope method using an autocollimator (f=200mm) with interchangeable objective lenses ○ Objective Lenses (Standard Equipment) ・f= 40mm ・f=100mm ・f=200mm ○ Measurement Range ・Reflection image: R= -100 to +200mm ・Transmission image: f= -100 to +200mm * Wider range of images can be measured with optional objective lenses ○ Resolution (Objective Lenses) ・f= 40mm - 0.104μm ・f=100mm - 0.260μm ・f=200mm - 0.520μm ● For more details, please refer to the PDF document or feel free to contact us. For more details, please refer to the PDF document or feel free to contact us.
【Specifications】 ○ Measurement Method: Transmission type ○ Applications - Eccentricity measurement (core accuracy measurement) - Centering (lens bonding work) ○ Measured Lenses: Convex lenses, concave lenses, bonded lenses ○ Measurement Range: Effective lens diameter φ3mm or more, BFL ±3mm to ±∞ ○ UBS Camera: Black and white 1/2 inch UBS camera ○ Power Supply: AC adapter AC100V–240V (50Hz/60Hz) ○ Dimensions: 155(W) × 333(H) × 255(D) mm, 4kg ○ Accessories: Main unit, dedicated analysis software, AC adapter, lens holder, dust cover, correction lens ○ Options: Standard three-jaw stage (φ15–φ76mm), large three-jaw stage motorized rotating stage, customized keyboard, UV fiber holder ● For more details, please refer to the PDF document or feel free to contact us. For more details, please refer to the catalog. Feel free to contact us.
【Specifications】 ○ Measurement method: Reflective type  ※ Transmissive/reflective compatible model: "US-A1000" ○ Measurement range  ・R=+15mm to -135mm (using 10X objective lens)  ・R=+80mm to -125mm (using f=100mm objective lens)  ・Lens diameter φ0.5mm and above ○ Minimum reading value  ・0.05μm (using 10X objective lens)  ・0.30μm (using f=100mm objective lens) ○ External dimensions: 180(W) × 400(H) × 280(D) mm; 6kg ● For more details, please refer to the PDF document or feel free to contact us. For more details, please refer to the PDF document or feel free to contact us.
---

---

---
  1. Featured Products
    Transmissive and reflective dual-purpose eccentricity measuring instrument "TR-A1"Transmissive and reflective dual-purpose eccentricity measuring instrument "TR-A1"
    overview
    【Specifications】 ○ Measurement Method: Combined Transmission and Reflection ○ Optical System: Microscope method using an autocollimator (f=200mm) with interchangeable objective lenses ○ Objective Lenses (Standard Equipment) ・f= 40mm ・f=100mm ・f=200mm ○ Measurement Range ・Reflection image: R= -100 to +200mm ・Transmission image: f= -100 to +200mm * Wider range of images can be measured with optional objective lenses ○ Resolution (Objective Lenses) ・f= 40mm - 0.104μm ・f=100mm - 0.260μm ・f=200mm - 0.520μm ● For more details, please refer to the PDF document or feel free to contact us.
    Application/Performance example
    For more details, please refer to the PDF document or feel free to contact us.
    Through-type eccentricity measuring instrument "CS-A1100"Through-type eccentricity measuring instrument "CS-A1100"
    overview
    【Specifications】 ○ Measurement Method: Transmission type ○ Applications - Eccentricity measurement (core accuracy measurement) - Centering (lens bonding work) ○ Measured Lenses: Convex lenses, concave lenses, bonded lenses ○ Measurement Range: Effective lens diameter φ3mm or more, BFL ±3mm to ±∞ ○ UBS Camera: Black and white 1/2 inch UBS camera ○ Power Supply: AC adapter AC100V–240V (50Hz/60Hz) ○ Dimensions: 155(W) × 333(H) × 255(D) mm, 4kg ○ Accessories: Main unit, dedicated analysis software, AC adapter, lens holder, dust cover, correction lens ○ Options: Standard three-jaw stage (φ15–φ76mm), large three-jaw stage motorized rotating stage, customized keyboard, UV fiber holder ● For more details, please refer to the PDF document or feel free to contact us.
    Application/Performance example
    For more details, please refer to the catalog. Feel free to contact us.
    Reflective eccentricity measuring instrument (compatible with ultra-small lenses) "US-A1"Reflective eccentricity measuring instrument (compatible with ultra-small lenses) "US-A1"
    overview
    【Specifications】 ○ Measurement method: Reflective type  ※ Transmissive/reflective compatible model: "US-A1000" ○ Measurement range  ・R=+15mm to -135mm (using 10X objective lens)  ・R=+80mm to -125mm (using f=100mm objective lens)  ・Lens diameter φ0.5mm and above ○ Minimum reading value  ・0.05μm (using 10X objective lens)  ・0.30μm (using f=100mm objective lens) ○ External dimensions: 180(W) × 400(H) × 280(D) mm; 6kg ● For more details, please refer to the PDF document or feel free to contact us.
    Application/Performance example
    For more details, please refer to the PDF document or feel free to contact us.